Biodiesel mini flow sensor
email: porter@microflowmeter.com ShanghaiJSN Micro Flow Meter CO.,LTD is an automatic meter production R&Denterprise approved by the Chinese government; it is mainly engaged in theresearch, development, and manufacturing of high-end technologies, processesand related equipment in the field of fluid measurement and control to meet theneeds of China and the world for fluid measurement and control equipment. Andthe higher requirements of the products. The company adopts internationaladvanced product design, manufacturing and management technologies, anddevelopment, produce the high quality super micro liquid flow meter,oval gearflow meter ,mass flow meter, circle spur gear flow meter,gear pump,gearmetering pump to meet China and world’s higher requirement. Wenot only has superior high-tech comprehensive capabilities and strict qualitymanagement, measurement management and other systems as well as improvedprocessing and testing methods, but also has a talent team that has madeimportant contributions to the development of flow meters and pumps in Chinaand the world.

Biodiesel mini flow sensor
Ovalgear flow meter is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.
Ovalgear flow meter is a new type of volumetric flowmeter, in addition to apositive displacement flowmeter with high accuracy, the flow is not sensitiveto other advantages, there are the following advantages: Wide range, usually inthe flow meter is 10: l, and Deep flowmeter is generally 100: 1, or even 1000:1, the accuracy is still above 0.5%, suitable for high pressure flowmeasurement, the maximum pressure can reach 100Mpa, especially suitable for themeasurement of small flow, the minimum measurement limit can be 0.3ml / min ,Less affected by the viscosity characteristics of the medium, suitable for flowmeasurement under various viscosity conditions.

Biodiesel mini flow sensor
The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

Biodiesel mini flow sensor
Maintechnical data of JSN micro oval Oval gear flow meter
CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"
CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"
CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"
CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"
CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"
CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"
CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"
Commonfault causes, troubleshooting
a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.
b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.
c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.
d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.